RolleSolutions.com

Canon CXDI 501G

The versatile CXDI-501G DR System expands the scope of Digital Radiography with exceptional diagnostic quality. Using Digital Radiography Systems can help to optimize the workflow, allowing healthcare professionals to concentrate on critical tasks. Configurations are available for upright stands, U-arm stands, Bucky tables or retrofit solutions.

High Resolution and High Sensitivity ~ With a 125 micron pixel pitch, the CXDI-501G Digital Radiography (DR) System delivers exceptional spatial resolution. The maximum 3 second exposure time allows this digital detector to be used with tomography equipment and for other exams that may require an exposure time of up to 3 seconds.
True Portability with Detachable Cable ~ Weighing less than 7 pounds, either the patient or the x-ray technician may comfortably hold the CXDI-501G DR System in place during image capture. The built-in groove in the detector also helps maneuver the detachable cable easily.
CXDI Control Software NE ~ The CXDI-70C Wireless Digital Radiography System uses the Canon CXDI Control Software NE. The intuitive operation of this software gives a wide range of selections directly from the main menu and yet images can be taken within three touches. The CXDI Control Software NE also has advanced image processing that shows the subtle details of trabecular bone structure and soft tissue in the same image. For more information, visit the Canon CXDI Control Software NE webpage.
Detector
Method Flat Panel Detector, Scintillator & Amorphous Silicon (a-Si)
Scintillator GOS (Gd2O2S: Tb)
Sensor LANMIT (Large Area New-MIS sensor and TFT)
Pixel Pitch 125 Microns
Pixels 2,800 x 3,408 Pixels (9.5 Megapixels)
Imaging Area Approximately 14 x 17 in (35 x 42.6 cm)
Standard Configuration Sensor Unit, Power Box, Remote Switch, X-ray Interface Cable
Image Acquisition and Processing
Image Processing Standard Advanced Multi-Frequency Processing
A/D 14-bit
Grayscale 4,096 Grayscale (12-bit)
Preview Image Approximately 3 Seconds After X-ray Exposure
Cycle Time Approximately 5 Seconds After X-ray Exposure
Data Output and Network Connection
Network Ethernet 10/100/1000 Base T, RJ45 Standard, Wireless Optional
DICOM DICOM 3.0 Compatible, Storage, Print, Modality Worklist, MPPS, and Storage Commitment
Electrical and Environmental
Operating Environment Sensor Unit: 41-95F (5-35C), Humidity 30-80% RH (non-condensing)
Physical Characteristics
Dimensions (W x L x H) 18.1 x 16.7 x 0.6 in (460 x 424 x 15 mm)Sensor Cable Length: 21 ft, 4.5 ft + 16.5 ft (7 m, 1.5 m + 5.5 m)
Weight 6.8 lbs (3 kg)

phone / fax: 510-727-0261